{"id":24,"date":"2023-07-11T19:36:57","date_gmt":"2023-07-11T17:36:57","guid":{"rendered":"https:\/\/webs.uab.cat\/nanerglab\/?page_id=24"},"modified":"2023-07-13T17:21:20","modified_gmt":"2023-07-13T15:21:20","slug":"equipament","status":"publish","type":"page","link":"https:\/\/webs.uab.cat\/nanerglab\/equipament\/","title":{"rendered":"Equipment"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\"><\/h2>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<p><strong>Setups and instrumentation<\/strong><\/p>\n\n\n\n<p>Optical table 1: HeNe laser vibrometer set-up with PSD deflection readout and photodetector for intensity modulation detection (1GHz) with optical chopper.<\/p>\n\n\n\n<p>Optical table 2: IR laser (1.55um) vibrometer with vacuum chamber and IR photodetector and 4-quadrant detector + diode laser deflection readout system.<\/p>\n\n\n\n<p>Optical Microscope Nikon ECLIPSE LV150N. Dark Field and Bright Field. Long working distance objectives 10X, 20X, 100X.<\/p>\n\n\n\n<p>Atomic Force Microscope Solver-Nano NT-MDT.<\/p>\n\n\n\n<p>Network analyzer Agilent E5061B (5Hz-3GHz)<\/p>\n\n\n\n<p>Oscilloscope\/Spectrum Analyzer Tektronix MDO 3024 (200MHz\/9kHz-3GHz)<\/p>\n\n\n\n<p>Signal generator Agilent 81150A<\/p>\n\n\n\n<p>Low-Noise Current Preamplifier Stanford Research Systems SR570<\/p>\n\n\n\n<p>Low-Noise Preamplifier Stanford Research Systems SR560<\/p>\n\n\n\n<p>Fluke 125 Industrial Scopemeter; DAQ-USB 6001 National Instruments.<\/p>\n\n\n\n<p>Piezo Nanopositioner PI-Micos 30 \uf06dm range and 0.2 nm resolution, and control electronics.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<p><strong>Hardware and software<\/strong><\/p>\n\n\n\n<p>Workstation Dual Cascade lake 16DIMMS,4xPCI. Processor Intel Xeon 4210R 10 Cores 2,4GHz 100W. DDR4 32GB 2933MHz. DDR4 32GB 2933MHz.<\/p>\n\n\n\n<p>COMSOL Finite Element Method code with MEMS and electromagnetism modules.<\/p>\n\n\n\n<p><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Setups and instrumentation Optical table 1: HeNe laser vibrometer set-up with PSD deflection readout and photodetector for intensity modulation detection (1GHz) with optical chopper. Optical table 2: IR laser (1.55um) vibrometer with vacuum chamber and IR photodetector and 4-quadrant detector + diode laser deflection readout system. Optical Microscope Nikon ECLIPSE LV150N. Dark Field and Bright [&hellip;]<\/p>\n","protected":false},"author":2708,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-24","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/webs.uab.cat\/nanerglab\/wp-json\/wp\/v2\/pages\/24","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/webs.uab.cat\/nanerglab\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/webs.uab.cat\/nanerglab\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/webs.uab.cat\/nanerglab\/wp-json\/wp\/v2\/users\/2708"}],"replies":[{"embeddable":true,"href":"https:\/\/webs.uab.cat\/nanerglab\/wp-json\/wp\/v2\/comments?post=24"}],"version-history":[{"count":6,"href":"https:\/\/webs.uab.cat\/nanerglab\/wp-json\/wp\/v2\/pages\/24\/revisions"}],"predecessor-version":[{"id":62,"href":"https:\/\/webs.uab.cat\/nanerglab\/wp-json\/wp\/v2\/pages\/24\/revisions\/62"}],"wp:attachment":[{"href":"https:\/\/webs.uab.cat\/nanerglab\/wp-json\/wp\/v2\/media?parent=24"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}