{"id":24,"date":"2023-07-11T19:36:57","date_gmt":"2023-07-11T17:36:57","guid":{"rendered":"https:\/\/webs.uab.cat\/nanerglab\/?page_id=24"},"modified":"2026-10-22T10:24:46","modified_gmt":"2026-10-22T08:24:46","slug":"equipament","status":"publish","type":"page","link":"https:\/\/webs.uab.cat\/nanerglab\/equipament\/","title":{"rendered":"Equipment"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div class=\"wp-block-group alignwide is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<p class=\"has-large-font-size wp-block-paragraph\"><strong>Setups and instrumentation<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Setup1:<\/strong> Optical table with HeNe laser vibrometer set-up with PSD deflection readout and photodetector for intensity modulation detection (1GHz) with optical chopper.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" width=\"1908\" height=\"1033\" class=\"wp-image-105\" style=\"width: 500px\" src=\"https:\/\/webs.uab.cat\/nanerglab\/wp-content\/uploads\/sites\/454\/2026\/10\/setup_HeNe.jpg\" alt=\"\" srcset=\"https:\/\/webs.uab.cat\/nanerglab\/wp-content\/uploads\/sites\/454\/2026\/10\/setup_HeNe.jpg 1908w, https:\/\/webs.uab.cat\/nanerglab\/wp-content\/uploads\/sites\/454\/2026\/10\/setup_HeNe-300x162.jpg 300w, https:\/\/webs.uab.cat\/nanerglab\/wp-content\/uploads\/sites\/454\/2026\/10\/setup_HeNe-1024x554.jpg 1024w, https:\/\/webs.uab.cat\/nanerglab\/wp-content\/uploads\/sites\/454\/2026\/10\/setup_HeNe-768x416.jpg 768w, https:\/\/webs.uab.cat\/nanerglab\/wp-content\/uploads\/sites\/454\/2026\/10\/setup_HeNe-1536x832.jpg 1536w, https:\/\/webs.uab.cat\/nanerglab\/wp-content\/uploads\/sites\/454\/2026\/10\/setup_HeNe-1200x650.jpg 1200w\" sizes=\"auto, (max-width: 1908px) 100vw, 1908px\" \/><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Setup2:<\/strong> Optical table with NIR laser (1.55um) vibrometer with vacuum chamber and NIR photodetector and 4-quadrant detector + diode laser deflection readout system.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" width=\"2560\" height=\"1920\" class=\"wp-image-130\" style=\"width: 500px\" src=\"https:\/\/webs.uab.cat\/nanerglab\/wp-content\/uploads\/sites\/454\/2026\/10\/setup_NIR-scaled.jpg\" alt=\"\" srcset=\"https:\/\/webs.uab.cat\/nanerglab\/wp-content\/uploads\/sites\/454\/2026\/10\/setup_NIR-scaled.jpg 2560w, https:\/\/webs.uab.cat\/nanerglab\/wp-content\/uploads\/sites\/454\/2026\/10\/setup_NIR-300x225.jpg 300w, https:\/\/webs.uab.cat\/nanerglab\/wp-content\/uploads\/sites\/454\/2026\/10\/setup_NIR-1024x768.jpg 1024w, https:\/\/webs.uab.cat\/nanerglab\/wp-content\/uploads\/sites\/454\/2026\/10\/setup_NIR-768x576.jpg 768w, https:\/\/webs.uab.cat\/nanerglab\/wp-content\/uploads\/sites\/454\/2026\/10\/setup_NIR-1536x1152.jpg 1536w, https:\/\/webs.uab.cat\/nanerglab\/wp-content\/uploads\/sites\/454\/2026\/10\/setup_NIR-2048x1536.jpg 2048w, https:\/\/webs.uab.cat\/nanerglab\/wp-content\/uploads\/sites\/454\/2026\/10\/setup_NIR-1200x900.jpg 1200w, https:\/\/webs.uab.cat\/nanerglab\/wp-content\/uploads\/sites\/454\/2026\/10\/setup_NIR-1980x1485.jpg 1980w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Microscopy:<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Optical Microscope Nikon ECLIPSE LV150N. Dark Field and Bright Field. Long working distance objectives 10X, 20X, 100X.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Atomic Force Microscope Solver-Nano NT-MDT.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Electronics instrumentation:<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Network analyzer Agilent E5061B (5Hz-3GHz)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Oscilloscope\/Spectrum Analyzer Tektronix MDO 3024 (200MHz\/9kHz-3GHz)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Signal generator Agilent 81150A<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Low-Noise Current Preamplifier Stanford Research Systems SR570<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Low-Noise Preamplifier Stanford Research Systems SR560<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Fluke 125 Industrial Scopemeter; DAQ-USB 6001 National Instruments.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Piezo Nanopositioner PI-Micos 30 um range and 0.2 nm resolution, and control electronics.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignwide is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<p class=\"wp-block-paragraph\"><strong>Hardware and software<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Workstation Dual Cascade lake 16DIMMS,4xPCI. Processor Intel Xeon 4210R 10 Cores 2,4GHz 100W. DDR4 32GB 2933MHz. DDR4 32GB 2933MHz.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">COMSOL Finite Element Method code with MEMS and electromagnetism modules.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Setups and instrumentation Setup1: Optical table with HeNe laser vibrometer set-up with PSD deflection readout and photodetector for intensity modulation detection (1GHz) with optical chopper. Setup2: Optical table with NIR laser (1.55um) vibrometer with vacuum chamber and NIR photodetector and 4-quadrant detector + diode laser deflection readout system. Microscopy: Optical Microscope Nikon ECLIPSE LV150N. Dark [&hellip;]<\/p>\n","protected":false},"author":2708,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-24","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/webs.uab.cat\/nanerglab\/wp-json\/wp\/v2\/pages\/24","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/webs.uab.cat\/nanerglab\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/webs.uab.cat\/nanerglab\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/webs.uab.cat\/nanerglab\/wp-json\/wp\/v2\/users\/2708"}],"replies":[{"embeddable":true,"href":"https:\/\/webs.uab.cat\/nanerglab\/wp-json\/wp\/v2\/comments?post=24"}],"version-history":[{"count":11,"href":"https:\/\/webs.uab.cat\/nanerglab\/wp-json\/wp\/v2\/pages\/24\/revisions"}],"predecessor-version":[{"id":133,"href":"https:\/\/webs.uab.cat\/nanerglab\/wp-json\/wp\/v2\/pages\/24\/revisions\/133"}],"wp:attachment":[{"href":"https:\/\/webs.uab.cat\/nanerglab\/wp-json\/wp\/v2\/media?parent=24"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}